The full-spectrum direct-reading OES spectrometer can be used for quality control and element content analysis in the processing of industries such as casting, smelting, machinery, aerospace, environmental protection, and university scientific research.
Quality control and analysis
Quality control and element content analysis in foundry, smelting, machinery, aerospace, environmental protection, university research and other industries
Ferrous metal alloys
Pig iron, cast iron, cast steel, steel and steel alloy (C, Si, Mn, P, S, Ni, Cr, Ti...)
Non-ferrous metal alloy
Aluminum, zinc, copper, nickel, cobalt, magnesium, lead, etc. (Si, Fe, Cu, Mg, Mn, Ni, Pb, Sb, Bi...)
Other special metal alloys
| Model | SES-2400 |
| Application Area | Elemental analysis in metallurgy, casting, machinery, scientific research, inspection, automotive, petrochemical, shipbuilding, electricity, aviation, nuclear power, metal and non-ferrous metal smelting, processing, and recycling industries |
| Detectable Substrate | Fe, Al, Cu, Mg, Zn, Ni, Ti, Sn, Pb, etc. |
| Detection | Atomic emission spectrometry |
| Optical System | Paschen-Runge architecture, Roland circle optical system |
| Light Room System | Intermittent vacuum system, vacuum pump works for 5 minutes/time, can maintain vacuum state >4 hours without inflation |
| Detection Wavelength Range | 120–800 nm |
| Roland Circle Radius | 400 mm |
| Dispersive Grating | Intermittent vacuum system, vacuum pump works for 5 minutes/time, can maintain vacuum state >4 hours without inflation (Note: This appears to be a duplicate entry from Light Room System; confirm if this is intentional or if it should describe the grating specifically, e.g., "Holographic diffraction grating") |
| Resolution | Better than 0.01 nm |
| Detector | High-performance CCD (up to 3648+46 pixels per block) |
| Pixel Size | 8 μm |
| Light Source | Digital light source, High Energy Precombustion Technology (HEPS) |
| Discharge Current | 1–100 A plasma current |
| Discharge Frequency | 100–1000 Hz |
| Detection Time | Generally 15–25 seconds/time |
| Correction Method | Reference analysis, automatic sample control correction |
| Light Room Constant Temperature | Ultra-thin constant temperature integrated light room, automatic constant temperature 35°C ± 0.2°C |
| Carrier Gas | 99.999% high-purity argon |
| Working Power Supply | 220 V / 50 Hz ± 5% |
| Power | Standby power: 75 W; Spectral excitation power: 700 W; Working power of vacuum pump: 500 W |
| External Dimensions | L684 × W584 × H350 mm |